BMPBX - 1706 FREE ALL

  • MSDS: BMPBX
  • Manufacturer: PRO CHEM INC
  • Product Name: 1706 FREE ALL
  • National Stock Number: 6850-00N025043
Product Identification

Product ID:1706 FREE ALL
MSDS Date:02/14/1991
FSC:6850
NIIN:00N025043
MSDS Number: BMPBX

Responsible Party
PRO CHEM INC
4420 BANKERS CIRCLE
DORAVILLE, GA 30360
US

Emergency Phone: 404-449-4040

Info Phone: 404-449-4040

Cage: 0CPM5

Contractor
PRO CHEM INC
ALPHARETTA, GA 30201 US

Telephone: 800-241-8180

Cage: 0CPM5

Ingredients

PROPANE,2-METHYL-; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000


BENZIN; (MINERAL SPIRITS)

CAS: 8030-30-6

RTECS: DE3030000


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHANOL; (METHYL ALCOHOL)

CAS: 67-56-1

RTECS: PC1400000

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


MINERAL OIL PETROLEUM DISTILLATES, SOLVENT - DEWAXED LIGHT

CAS: 64742-56-9

RTECS: PY8039500


METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM/450STEL;9394

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NOT DETERMINED-SEE APPROP PEL RATING
ON ITEMS LISTED IN INGREDS, PRIMARLY RTES OF ENTRY WOULD BE INGEST,
& INHAL, & CONTACT ON ALL BODY PARTS.
Explanation of Carcinogenicity:CAS NO. 64742-56-9 IARC GROUP 1
Effects of Overexposure:DIZZINESS. CHLOROCARBON MATL HAVE PRODUCED/
SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS AND COULD
HAVE SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE)
MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:INHALATION MAY CAUSE NASAL
IRRITATION.

First Aid

First Aid:INHAL:PROVIDE O2. INGEST: CALL MD IMMED . SKIN:FLUSH WITH
COPIOUS AMOUNTS OF WATER. CALL MD . EYES:IMMED FLUSH WITH POTABLE
WATER FOR A MINIMUM OF 15 MIN, SEEK ASSISTANCE FROM MD .

Fire Fighting

Flash Point:45.0F,7.2C
Lower Limits:1.2%
Upper Limits:7%
Extinguishing Media:CO2, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE

Accidental Release

Spill Release Procedures:CLEAN WITH SAFETY SOLVENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL AREA.
Other Precautions:AEROSOL UNDER PRESS 35@70F. DO NOT STORE ABOVE 120F.
OBSERVE LBL WARNINGS ON USE. NO SMOKING IN AREA OF USE. DO NOT USE
IN GEN VICINITY OF ARC WELD, OPEN FLAMES/HOT SURF. HEAT &/OR UV
RADIA MAY CAUSE FORMATION OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Work Hygienic Practices:NORMAL HYGIENE PRACTICES.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:147F,64C
Spec Gravity:0.81
Solubility in Water:0
Appearance and Odor:OPAQUE GREY GREEN SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
UNKNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:CO, CO2, HCL. PHOSGENE .

Disposal

Waste Disposal Methods:APPROVED LANDFILL. DISPOSE OF IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.